STI-100 Removal
Step 1: Remove the left side plate to expose the STI-100.
Step 2: Disconnect the STI-100 from the motor. You will now have the red, black, and white motor wires available.
Step 3: Remove the two screws securing the RJ-45 port to the back of the enclosure, then remove the STI-100.
IMC Installation
Step 1: Feed the IMC motor wire leads through the opening where the RJ-45 port was located. Connect the IMC wires to the motor using wire-nuts, matching each wire color to the corresponding motor wire. Refer to the attached IMC wiring diagram.
Step 2: Remove the cover from the IMC. Feed the IR cable into the enclosure and plug it into the middle CS-Bus RJ-25 port. This is the powered port.
Step 3: Reinstall the IMC cover, connect the IMC power supply, and test the system to verify proper operation.
Comments